Switchable glass engineered in India · Pan-India survey & installation

Applications

Hospitals, ICUs and consultation rooms

Healthcare asks two contradictory things of a partition: staff need to observe, patients need dignity. Switchable glass is one of the few ways to deliver both from the same pane.

Why healthcare specifies it

Observation and dignity

Clear for continuous clinical observation; opaque instantly for examinations, procedures and family visits.

Infection control

A flat, wipe-clean surface. Curtains harbour pathogens, need laundering and are a recognised infection-control weak point.

No fabric, no dust

Removes cubicle curtains from the cleaning and replacement cycle entirely.

Faster than curtains

Sub-second switching at a wall control — no reaching across a bed to draw a rail.

Daylight to the ward core

Glazed bays let daylight reach interior spaces, which is associated with better patient outcomes.

Reduced noise

Laminated units damp sound between bays, supporting both rest and confidentiality.

Critical care requires backup power. PDLC fails opaque, so a power cut removes staff line of sight into an ICU bay. Panels in critical care must sit on UPS or generator circuits — see what happens in a power cut.

How we specify healthcare installations

  • Laminated safety glass throughout — wipe-clean and shatter-resistant
  • Critical-care panels on UPS or generator-backed circuits
  • Controls at the bay entrance, reachable without crossing the bed
  • Flush detailing with no ledges or fabric to harbour contamination
  • Fail state verified against your clinical observation protocol
  • Neutral-cure sealants compatible with hospital cleaning regimes

Typical healthcare budgets

ApplicationAreaIndicative total
Single ICU bay~90 sq ft₹2.3L – ₹4.2L
Consultation room~110 sq ft₹2.8L – ₹5.1L
Nurse station screen~50 sq ft₹1.4L – ₹2.4L
8-bay ICU ward~720 sq ft₹17L – ₹31L

Healthcare questions

What happens to an ICU bay in a power cut?

The glass turns opaque, which removes staff line of sight. For critical care this is a genuine clinical consideration, and those panels should be on backup power. The load is small — roughly 5W per square metre — so a modest UPS covers a full ward.

Does it meet infection-control requirements?

The glass is a flat, non-porous, wipe-clean surface with no fabric, which compares favourably with cubicle curtains. Compliance depends on your institution's protocol, so we supply the material specification for your infection-control team to assess.

Can it be cleaned with hospital disinfectants?

Most standard disinfectants are fine. Ammonia-based and strong solvent cleaners should be avoided. Send us your cleaning schedule and we will confirm compatibility before order.

Can it be installed in a live ward?

Yes, phased bay by bay. We plan around clinical schedules and work out of hours where required. Retrofit film is faster if the existing glazing is suitable.

Request a quote

Get an itemised price

Send us the area and space type. You will have a written, line-by-line quotation within one business day — including controls and installation, not just the glass.